A quantum leap in perfusion technology Sorin’s fifth-generation modular heart-lung machine has set new standards for functionality, flexibility and quality. Designed for many years of demanding performance, the advanced design allows for:. Better integration with the perfusion circuit. More configuration options to accommodate a greater assortment of procedures (including pediatric).

  1. Stockert S5 Manual
  2. Stockert S5 User Manual

Quick and easy exchange of individual components in the most challenging environments. Unprecedented safety features As upgrades can be implemented at any time, the S5 system will remain state-of-the-art for many years to come. Addressing individual needs From a small, compact HLM equipped with three roller pumps to a full-featured system with seven roller pumps and the full range of control and monitoring functions, the S5 can be configured to individual requirements and budget considerations.

Modularity From a small, compact HLM equipped with double-head pumps to a five-position system with extended masts, the S5 can be configured to your budget considerations. Console for 3 to 5 roller pumps. 2 additional roller pumps can be mounted on the mast.

Panel with 3, 4 or 6 display modules. Flexible mast system Safety All of the warnings and automated alarms of the S5 system are recorded and listed chronologically on the system display panel.

Information and incidents cannot get lost, and critical situations can be quickly detected and cleared. Full text messages for alarms and warnings. One key each for muting, clearing and overriding alarms. Differentiated alarm tones. Quick and easy replacement of all DCMs. UPS can bridge a power failure up to 130 minutes (20 minutes at full load) Flexibility The S5 was designed to meet the diverse needs of today's hospital—and then keep pace with you as your needs change. SIII and SIII Encore™ system users can transfer their external devices such as data management system or SCP to the new S5 System.

They easily connect to the S5 using an adapter cable. Pump heads can be rotated into position to optimize tubing layout. Two vertically and one horizontally moveable masts for mounting external devices and disposables. Up to four TFT displays can be stacked vertically in the mast panel and each can be configured according to your required perfusion parameters Technology The S5's memory chips are located within the various modules instead of centrally in a CPU. This ensures that each component functions as designed, in real-time.

In addition, each module is completely replaceable and interchangeable.

The perfusion record, whether manually recorded or computer generated, is a legal representation of the procedure. The handwritten perfusion record has been the most common method of recording events that occur during cardiopulmonary bypass. This record is of significant contrast to the integrated data management systems available that provide continuous collection of data automatically or by means of a few keystrokes. Additionally, an increasing number of monitoring devices are available to assist in the management of patients on bypass.

These devices are becoming more complex and provide more data for the perfusionist to monitor and record. Most of the data from these can be downloaded automatically into online data management systems, allowing more time for the perfusionist to concentrate on the patient while simultaneously producing a more accurate record. In this prospective report, we compared 17 cases that were recorded using both manual and electronic data collection techniques. The perfusionist in charge of the case recorded the perfusion using the manual technique while a second perfusionist entered relevant events on the electronic record generated by the Stockert S3 Data Management System/Data Bahn (Munich, Germany). Analysis of the two types of perfusion records showed significant variations in the recorded information. Areas that showed the most inconsistency included measurement of the perfusion pressures, flow, blood temperatures, cardioplegia delivery details, and the recording of events, with the electronic record superior in the integrity of the data. In addition, the limitations of the electronic system were also shown by the lack of electronic gas flow data in our hardware.

Our results confirm the importance of accurate methods of recording of perfusion events. The use of an automated system provides the opportunity to minimize transcription error and bias. This study highlights the limitation of spot recording of perfusion events in the overall record keeping for perfusion management. The perfusion record is a legal record of the cardiopulmonary bypass (CPB) procedure and should be an accurate and legible document. Traditionally, the perfusion record has been handwritten, with the perfusionist documenting specific parameters and events, often every 5–10 minutes or when changes in monitored parameters occur or events dictate documentation (e.g., drug administration). This manual method of data collection produces a record that can be filed into the medical record; however, these records are often inadequate (–).

The manual record cannot offer a complete picture of what has occurred during the bypass period, with errors able to be introduced in a number of ways. These inadequacies include missing data, such as when the perfusionist is distracted by more pressing events; biased recording of information; transcription error; and subjectivity of observation. The accuracy of recording intraoperative data has been examined in anesthesia, where computer-generated records have been compared with handwritten records, and the quality of the data collected examined (–).

Each of these papers reported a bias in the handwritten records when blood pressures were recorded, finding that, when actual blood pressures were lower or higher than expected, the recorded data points were normalized toward the expected rather than the actual value. They concluded that the handwritten anesthetic record should not be relied on as a source of accurate data for research. All of these issues give rise to the question of the integrity of the data documented manually.

How accurate is this record of events that actually occurred? The manual record only produces a snapshot of the CPB procedure, and it is not possible to extrapolate what has occurred between recorded events.

In legal cases, expert perfusionists may be consulted to fill in the gaps of a manual record; however, the value of this input is questionable. There has been a gradual evolution of electronic data output from monitoring devices available in the cardiac operating room, which facilitates the recording of this information into an electronic database. The variety of different technologies capable of outputting electronic data has expanded, now including most electronic devices in the operating room (e.g., anesthetic machines, blood gas analyzers, perfusion systems, and other point-of-care analyzers). In addition, the ability of electronically generated records to integrate with hospital information systems and databases is now common. Unfortunately, most of the technology available today has not been embraced with enthusiasm or used to its full capacity.

There are a number of heart lung machine systems that are able to generate an electronic record with the aid of data collection software. These systems have automatic data acquisition and integrate data from the pump system and other monitoring systems in the operating room. The management of the cardiac surgical patient in the operating room is increasing in complexity, with an increasing number of monitoring devices assisting in the management of patients before, during, and after CPB. This results in more data for the perfusionist to monitor, record, and respond to. If the data from these devices is recorded automatically, it allows more time for the perfusionist to concentrate on the conduct of CPB rather than on documenting the procedure manually.

Manual entry is minimized with data collection software, being required only for events that are unable to be electronically detected and is often accomplished by simple single keystroke entry. Heart lung machine systems incorporating some degree of automatic data management have been available for many years; however, most clinical units using these systems have not fully used the technology available. Many prefer to record data manually. In addition, there are software solutions available that can be used in conjunction with manual data recording to integrate data such as PerfBase (and Perfusion Data Solutions (West Terre Haute, IN) that allow charting, quality control, and reporting features.

The integrity of the data in these systems may still be open to bias, because the data entry can be configured to require manual input. In this prospective study, we compared two different methods of perfusion data collection: automatic data collection, using the Data Management System (DMS; Stockert, Munich, Germany), and the traditional manual perfusion record. Surgical and Perfusion Management All patients received a moderate fentanyl-based anesthetic technique. CPB surgery was performed using the Stockert S3 (Munich, Germany) roller pump heart lung machine and Hemotherm heater cooler unit (Cincinnati Sub Zero, Cincinnati, OH).

CPB was initiated after cannulation of the aorta (21-Fr cannula) and the right atrium (single 36-Fr dual-stage cannula) for venous drainage. Bicaval cannulation was used for the ASD repair (32-Fr cannula). The circuit consisted of a Capiox SX25 (Terumo Corporation, Tokyo, Japan) membrane oxygenator, a Jostra 40-1 arterial filter (Hirrlingen, Germany), PVC tubing (Cobe, Denver, CO), and a crystalloid prime of 1600-ml (consisting of 100 ml Hartmann, 1000 ml plasmalyte 148, 500 ml gelofusine, 50 ml sodium bicarbonate 8.4% and 10,000 U of heparin). Alpha stat blood gas management protocol was used. Activated clotting time (ACT) was measured using the Hemochron 401 (International Technidyne Corporation, Edison, NJ), and maintained above 400 seconds.

Patients were allowed to drift to 34°C and received antegrade blood cardioplegia with an initial dose (500 ml) of tepid high potassium (30 mM KCl) blood cardioplegia (4:1, delivered at 250 ml/min at 32°C) to induce asystole. In addition, low potassium (15 mM KCl) blood cardioplegia was given to maintain asystole or at approximately 20-minute intervals. Mean arterial blood pressure (MAP) was maintained between 40 and 70 mmHg. No cases were vented; however, a pump sucker was used in the ASD repair.

All cases were performed by one perfusionist (J.O.), one of two surgeons, and one of three anesthetists. All routine functions such as rewarming, assessment of transfusion requirements, and administration of pharmacological and volatile agents were performed in the usual manner according to institutional protocol by the perfusionist in charge.

Manual Data Collection The perfusionist in charge of conducting CPB recorded the procedure using the manual technique. The manual record was documented in accordance to institutional protocols, with patient parameters recorded every 5–10 minutes or if changes occurred.

Stockert S5 Manual

The parameters recorded were time and major events, MAP, venous pressure, line pressure, venous saturation, hematocrit, and nasopharyngeal, arterial, and venous blood temperatures. Blood gas analysis was undertaken approximately 10 minutes after the initiation of CPB, 3 minutes after cross-clamp removal when rewarming, and every 30 minutes.

Stockert

All information was transcribed temporally onto the pump sheet when possible. Data were collected in a routine manner from the prebypass period until the completion of CPB. Automated Electronic Data Collection A second perfusionist (A.M.), present for the entire procedure, entered relevant events into the electronic record using the DMS. The DMS was configured to collect data at 20-second intervals from the S3 heart lung machine (Stockert), S5 anesthetic monitor (Datex-Ohmeda, Helsinki, Finland), and the Biotrend venous saturation monitor (Medtronic, Minneapolis, MN).

Data were also collected electronically from the ABL725 blood gas analyzer (Radiometer, Copenhagen, Denmark) after blood gas analysis. The DMS was run on a Compaq Armada E500 Pentium III laptop computer (Hewlett Packard, Palo Alto, CA) using a Windows 2000 operating system (Microsoft Corporation, Redmond, WA). Intraoperative data were collected from patient intubation until the CPB circuit lines were returned by the surgeon.

Events, such as drug addition, were entered manually by keystrokes into the laptop. The blood gas result was accepted by a single keystroke to confirm that the perfusionist had seen the results and for data storage. RESULTS Analysis of the perfusion records generated manually and electronically highlighted significant variations in the type of information and the quantity of recorded information. We identified the following areas to show the most inconsistency, the most obvious being the difference in the number of time-points for which data were collected. The electronic record was configured to record data every 20 seconds, which for our average bypass time of 52 minutes, resulted in 156 sets of data during bypass. The manually recorded data were only recorded on average 15.5 times per case, with the time interval between entries ranging from 2.7 to 6.2 minutes. The average number of data points collected in the automatic (spotted bar) vs.

Manually (striped bar) collected records. There was also a large difference in the number of procedural events recorded. Most major events were recorded on the manual record during the procedure (e.g., X clamp application, drug administration, and blood gas results); however, on the electronic record, these events and many additional events (e.g., activation of electronic low level or air bubble alarms) were captured. These additional events were not documented on the manual record.

Shows the difference in the actual data recorded by both methods. Highlighted in this comparison of the MAP for an entire case is the failure of the manual record to capture the maximum and minimum pressures actually reached during bypass. This comparison also highlights that data were not collected from the initiation and weaning of CPB on the manual form, because the perfusionist was not able to record manually the parameters before bypass because of other duties. Example of blood flow collected both manually and automatically. Blood flow is plotted against the time for both the manual (.) and automatic records (▪). Is a record of arterial outlet temperature, which is similar for either method; however, the manual data collection method failed to record extremes. There were differences in the rate of rewarming between the two records, and a failure to capture the maximum temperature and minimum temperature was evident.

The arterial outlet temperature across all records varied from 33.3°C (manual record) to 31.2°C (electronic); the range of variation was 0.7–6.9°C ( p =.002). The maximum mean temperature recorded manually was 37.6°C, whereas electronically, temperatures in excess of 38°C were recorded, with temperature differences ranging from −1.3 to 0.1°C ( p =.001). This inconsistency was also evident in the nasopharyngeal temperatures , with the mean minimum nasopharyngeal temperature recoded manually being 34.2°C compared with 33.7°C, which was recorded electronically. The range of the difference between records was −0.6°C to 3.2°C. The maximum nasopharyngeal temperature also showed variation, with a manual mean temperature of 36.4°C compared with 37.2°C being recorded electronically (range of difference, −1.6°C to 1°C; p. DISCUSSION Significant differences in reported data were apparent on a number of the parameters (e.g., MAP, temperature), as well as the range of values reported, between the two methods of reporting, indicating the large variability between techniques.

These findings do raise questions, such as “how important is it to accurately report what is occurring during bypass?,” “is the minimum pressure reached during a case important?,” and “is it acceptable to report a pressure that has an error of 50%?” The answer to these questions is complex; however, there can be no surrogate for accurate record keeping during cardiac surgical procedures. Our findings reflected those reported in similar studies evaluating record keeping in anesthesia. For example, with MAP values, the extremes seen in the electronic record were minimized in the handwritten record (–).

These results show the improved accuracy of recording perfusion events using an electronic data acquisition system and highlight the inadequacies produced by spot recording, with the manual record failing to capture critical events, such as maximum and minimum MAPs and temperatures. The integrity of the data from automatic data acquisition removes the bias that is produced in the manual record. The ease at which events can be documented in the electronic record, such as a few keywords or keystrokes, gives the perfusionist greater ability to concentrate on performing CPB. This facilitates optimal patient management because it removes the task of manually documenting routine parameters, especially when more urgent events happen.

In fact, if “emergency” events do occur, the automated record provides data for the period that may otherwise not be available. This can aid in analysis of the event and the development of strategies to better cope with perfusion emergencies, such as oxygenator failure. The collection and recording of an accurate electronic record should be seen as beneficial, providing support for clinical practices. The premise is that if CPB is being performed according to institutional protocol, the data collected will reflect this.

When an adverse outcome occurs, the electronic record additionally should be a valuable source of information because it records actual time-related events that have occurred and does not require “expert advice” to speculate on what “may have” actually happened. There are, however, limitations to automatic data acquisition, such as recording of artefacts. For example, the flushing of a central venous pressure (CVP) monitoring line would produce a false CVP reading. This can be overcome by either a manual entry made at the time of the artefact or producing data analysis filters that reject artefacts (e.g., CVP 50). In this study, artefacts were filtered manually in the evaluation of the data.

Stockert S5 User Manual

Similarly, our system did not incorporate an electronic gas flow monitor, resulting in a second perfusionist occasionally recording this information into the DMS. An electronic flow meter or blender would rectify this. As per our clinical protocol, whenever the gas flow was altered, this change was documented. The use of an automated system provides the opportunity to minimize transcription error and remove observer bias. Its potential at this time seems limitless, with one major application being the development of “real time” feedback for the perfusionist during the case, resulting in a potential change in patient management during bypass and the use of the collected data for the purpose of quality control.